Table 4-1 shows the technical specifications of the BTS3902E.
Item
| Specification
|
Frequency Band
| Frequency Band
| Receive Frequency Band (MHz)
| Transmit Frequency Band (MHz)
|
1900 MHz
| 1850 to 1910
| 1930 to 1990
|
2100 MHz
| 1920 to 1980
| 2110 to 2170
|
Capacity
| Two cells
Uplink: 192 CEs
Downlink: 192 CEs
|
Output power
| The BTS3902E supports two carriers. The output power of the antenna connector in the RF module is 2×5 W.
l Supports single output or MIMO
l Single output: the maximum output power for each transmit channel is 5 W
l MIMO: the maximum output power is 5 W+5 W
l Supports configuration of power amplifiers with different power
The maximum output power equals the maximum output power of the power amplifier minus the internal loss. The maximum output power is measured at the antenna connector in the RF module.
|
Receiver sensitivity
| Frequency Band
| Receive Diversity Sensitivity for Single Antenna (dBm)
| Receive Diversity Sensitivity for Double Antenna (dBm)
|
1900 MHz/2100 MHz
| -123.0*
| -125.8*
|
*As recommended in 3GPP TS25.104, receiver sensitivity is measured at the antenna connector on the condition that the data rate over the channel reaches 12.2 kbit/s and the Bit Error Rate (BER) does not exceed 0.001.
|
Internal antenna
| Gain
| > 6 dBi
|
Polarization mode
| ±45°
|
Directionality
| Directional
|
Vertical lobe width (3 dB)
| > 33°
|
Horizontal lobe width (3 dB)
| > 60°
|
VSWR
| < 2
|
Transmission ports
| FE/GE electrical port, FE/GE optical port
|
Clock synchronization
| IP clock (IEEE 1588V2) is synchronous with the Ethernet clock.
Precision: 0.05 ppm
|
Dimensions (height x width x depth)
| 300 mm x 270 mm x 120 mm (without the antennas and case)
300 mm x 280 mm x 145 mm (with the antennas and case)
|
Weight
| 11 Kg (without the antennas and the case)
13 Kg (with the antennas and the case)
|
Input voltage
| Single phase: 100/200V AC to 120/240V AC
Voltage range: 90/180V AC to 135/290V AC
|
Power consumption
| Frequency band: 1900 MHz
|
MIMO Configuration
| Output Power per Carrier (W)
| Typical Value (W)
| MaximumValue (W)
|
1×1
| 2×5
|
|
|
1×2
| 2×2.5
|
|
|
Non-MIMO Configuration
| Output Power per Carrier (W)
| Typical Value (W)
| MaximumValue (W)
|
1×1
|
|
|
|
1×2
|
|
|
|
Frequency band: 2100 MHz
|
MIMO Configuration
| Output Power per Carrier (W)
| Typical Value (W)
| MaximumValue (W)
|
1×1
| 2×5
|
|
|
1×2
| 2×2.5
|
|
|
Non-MIMO Configuration
| Output Power per Carrier (W)
| Typical Value (W)
| MaximumValue (W)
|
1×1
|
|
|
|
1×2
|
|
|
|
l The typical power consumption level is reached when the base station works with 40% load, and the environment temperature is 25°C.
l The maximum power consumption level is reached when the base station works with 100% load, and the environment temperature is 25°C.
|
Temperature
| -40°C to +45°C (with solar radiation)
-40°C to +50°C (without solar radiation)
|
Relative humidity
| 5% RH to 100% RH
|
Relative humidity
| 1 g/m3 to 30g/m3
|
Air pressure
| 70 kPa to 106 kPa
|
Protection level:
| IP55
|
Storage environment
| ETSI EN300019-1-1 V2.1.4 (2003-04) Class1.2 "Weatherprotected, not temperature-controlled storage locations".
|
Transportation environment
| ETSI EN300019-1-2 V2.1.4 (2003-04) Class 2.3 "Public transportation".
|
Anti-seismic performance
| EC 60068-2-57 (1999-11) Environmental Testing – Part 2-57: Tests – Test Ff: Vibration – Time-history method.
YD5083-99: Interim Provisions for Test of Anti-seismic Performance of Telecommunications Equipment.
|
Electromagnetic compatibility
| The BTS3902E can meet the demand of electromagnetic compatibility and is in accordance with the following standards:
l CISPR 22 (1997)
l EN 55022 (1998)
l EN 301 489-23 V1.2.1 (2002-11)
l CISPR 24 (1998)
l IEC 61000-4-2
l IEC 61000-4-3
l IEC 61000-4-4
l IEC 61000-4-5
l IEC 61000-4-6
l IEC 61000-4-29
l GB 9254-1998
l ETSI 301 489-1 V1.3.1 (2001-09)
l FCC Part 15
The BTS3902E has passed the CE (Conformité Européenne) certification.
|
| | | | | | | | |